RoHS exemptions

RoHS Annex IV exemption 1: Lead, cadmium and mercury in detectors for ionising radiation

Annex IV 1 covers: Lead, cadmium and mercury in detectors for ionising radiation. The annex entry states no expiry date.

2026-11-05Directive 2011/65/EU (RoHS), consolidated text; https://eur-lex.europa.eu/legal-content/EN/TXT/?uri=CELEX:02011L0065-20260701

Notify me

Annex
Annex IV: Applications exempted from the restriction in Article 4(1) specific to medical devices and monitoring and control instruments
Entry
1
Section of the annex
Equipment utilising or detecting ionising radiation
Expiry in the annex
No expiry date stated in the annex entry
Version
Consolidated version of 1 July 2026
Official source
Directive 2011/65/EU (RoHS), consolidated text

Entry (official wording)

Lead, cadmium and mercury in detectors for ionising radiation.

Date wording in the entry

The annex states no date for this entry.

Validity and renewal

Article 5(5) of the directive: "An application for renewal of an exemption shall be made no later than 18 months before the exemption expires. The existing exemption shall remain valid until a decision on the renewal application is taken by the Commission." This site does not show whether a renewal application for this entry is pending or decided.

Article 5 of the directive sets validity periods and the renewal procedure for exemptions in Annexes III and IV. Its wording is quoted on the Sources and method page. This page repeats only what the annex says about this entry.

Neighbouring entries in Annex IV

Using Annex IV exemption 1: expiry, equipment categories, declaration

Expiry and renewal: the annex entry states no expiry date. The consolidated text marks this entry as text of the directive as adopted in 2011. For exemptions listed in Annex IV as at 21 July 2011, Article 5(2) sets a maximum validity period of 7 years from the dates in Article 4(3), unless a shorter period is specified, which may be renewed. Article 4(3) gives 22 July 2014 for medical devices and monitoring and control instruments, 22 July 2016 for in vitro diagnostic medical devices and 22 July 2017 for industrial monitoring and control instruments. Article 5(5) of the directive asks for a renewal application no later than 18 months before an exemption expires and keeps the existing exemption valid until the Commission decides on that application; under Article 5(6), a rejected renewal ends the exemption 12 to 18 months after the decision.

Whether a renewal application for this entry is pending, or the Commission has decided on it, is not recorded in the consolidated text. Directive (EU) 2025/2456 of the European Parliament and of the Council of 26 November 2025, which applies from 13 August 2027 and is not in the consolidated text of 1 July 2026, moves applications to the European Chemicals Agency and keeps the rule that the existing exemption stays valid until the Commission decides.

Amending act: the consolidated text marks no amending act on this entry.

Equipment categories: Annex IV is titled "Applications exempted from the restriction in Article 4(1) specific to medical devices and monitoring and control instruments". In Annex I of the directive these are category 8, Medical devices, and category 9, Monitoring and control instruments including industrial monitoring and control instruments.

Declaration of conformity and technical file: Article 7 of the directive has manufacturers draw up the technical documentation (point b) and an EU declaration of conformity (point c), and keep both for 10 years after the equipment is placed on the market (point d). Annex VI sets the content of the declaration; it has no line for exemptions, and its point 7 is "Additional information". The annex numbers this entry 1 in Annex IV.